<option id="o3fjs"></option>
        <tbody id="o3fjs"><nobr id="o3fjs"><dfn id="o3fjs"></dfn></nobr></tbody>
        <progress id="o3fjs"><bdo id="o3fjs"><strong id="o3fjs"></strong></bdo></progress>
        <samp id="o3fjs"><ins id="o3fjs"><ruby id="o3fjs"></ruby></ins></samp><tbody id="o3fjs"></tbody>

          <menuitem id="o3fjs"><ins id="o3fjs"><u id="o3fjs"></u></ins></menuitem>
        1. <progress id="o3fjs"><bdo id="o3fjs"><strong id="o3fjs"></strong></bdo></progress>

          <menuitem id="o3fjs"><ins id="o3fjs"></ins></menuitem>

          Phone:

          +86-516-86483788

          Variable-frequency motors and fans are produced and sold

          "Innovation, green, win-win" business philosophy

          GBT?Series?Flameproof?Axial?Flow?Fan

          ①The elevation of the installation site shall not exceed 1000m.
          ②Working environment temperature: -20~+40℃.
          ③The average monthly maximum relative humidity in the wettest month is 90%, while the average minimum temperature in that month is not higher than 25℃.
          ④The working power supply is AC380V±10%.
          ⑤No violent vibration and impact.

          TEL:+86-516-86483788

          1.The flameproof performance of the fan is combined with the provisions of GB3836.2-2000 to make the flameproof type.Explosion-proof marks a Exd Ⅱ BT4. & have spentApply to factory Ⅱ, Ⅱ B level, temperature classes for T1 ~ T4 group of the gas or vapor and air form for the sites with explosive air mixture of 1 division, 2 division.

          2.The fan carries the medium of air or air and other non-corrosive gas mixtures with the maximum total pressure not higher than 1000Pa.The inlet temperature of the medium shall not exceed 40℃.The content of dust and other solid impurities in the medium shall not be more than 100mg/m3.

          3.The fan should be able to run rated when it is used under the following conditions.

          ①The elevation of the installation site shall not exceed 1000m.

          ②Working environment temperature: -20~+40℃.

          ③The average monthly maximum relative humidity in the wettest month is 90%, while the average minimum temperature in that month is not higher than 25℃.

          ④The working power supply is AC380V±10%.

          ⑤No violent vibration and impact.

          4.Types of meaning

          The contour map:

          Main technical parameters:

          Model Electric system Power
          W
          Speed
          r/min
          Air volume
          m³/h
          Wind pressure
          Pa
          Noise
          dB(A)
          D
          mm
          L1
          mm
          L2
          mm
          L3
          mm
          α
          mm
          A
          mm
          R
          mm
          N
          mm
          GBT-80 triple-phase
          380V
          50Hz
          40 1400 160 30 65 158 15 40 180 1.5 5 3.5 3
          GBT-90 40 1400 250 40 65 177 16 45 186 1.5 5 3.5 3
          GBT-100 45 1400 300 42 67 195 18 70 200 1.5 5 3.5 3
          GBT-112 45 1400 500 55 70 220 22 71 200 1.5 5 3.5 3
          GBT-132 45 1400 600 50 68 260 22 81 210 1.5 5 3.5 4
          GBT-160 45 1400 900 45 70 316 24 100 226 1.5 5 3.5 4
          GBT-180 120 1400 1200 55 70 357 40 118 278 1.5 5 3.5 4
          GBT-200 220 1400 1800 65 72 396 40 127 290 2.0 6 4.5 4
          GBT-225 220 1400 2700 80 74 447 45 131 295 2.0 6 4.5 4
          GBT-250 220 1400 3300 85 76 486 55 157 360 2.0 6 4.5 4
          GBT-280 370 1400 4000 110 76 550 65 172 380 2.0 9 5.5 4
          GBT-315 370 1400 5200 150 77 619 72 178 455 2.0 9 5.5 4
          GBT-355 450 900 6200 100 82 698 82 185 475 2.0 12 6.5 4

          熟女视频